Something is either restricting the gate when it reaches the closed position activating the sensitivity mechanism to reopen the gate or the sensitivity is just set too high.
- Put the gate into manual mode and push the gate closed but push the gate very slowly. You want to try detecting any changes in the resistance to the movement of the gate when it reaches the closed position. If you notice that you must push harder at the end or something is catching the gate, try and identify what it is and resolve this.
- Check that when the gate closes, it moves smoothly into its closed catch bracket – make sure that even if the gate wobbles slightly from side to side it is not going to hit the catch. Once again if this is the case try and open up the catch.
- Lastly reduce the sensitivity of the operator. Visit our website – CENTSYS Systems. Read from page 27 of the manual. You must programme at MENU LEVEL 7 – 3 flashes of the STATUS LED. (this will give you LOW sensitivity)